Evaluation of pharmacokinetic models for perfusion imaging with dynamic contrast-enhanced magnetic resonance imaging in porcine skeletal muscle using low-molecular-weight contrast agents

Hindel, Stefan and Papanastasiou, Giorgos and Wust, Peter and Maaß, Marc and Söhner, Anika and Lüdemann, Lutz (2018) 'Evaluation of pharmacokinetic models for perfusion imaging with dynamic contrast-enhanced magnetic resonance imaging in porcine skeletal muscle using low-molecular-weight contrast agents.' Magnetic Resonance in Medicine, 79 (6). pp. 3154-3162. ISSN 0740-3194

Full text not available from this repository. (Request a copy)

Abstract

Purpose Pharmacokinetic models for perfusion quantification with a low‐molecular‐weight contrast agent (LMCA) in skeletal muscle using dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI) were evaluated. Methods Tissue perfusion was measured in seven regions of interest (ROIs) placed in the total hind leg supplied by the femoral artery in seven female pigs. DCE‐MRI was performed using a 3D gradient echo sequence with k‐space sharing. The sequence was acquired twice, first after LMCA and then after blood pool contrast agent injection. Blood flow was augmented by continuous infusion of the vasodilator adenosine into the femoral artery, resulting in up to four times increased blood flow. The results obtained with several LMCA models were compared with those of a two‐compartment blood pool model (2CBPM) consisting of a capillary and an arteriolar compartment. Measurements performed with a Doppler flow probe placed at the femoral artery served as ground truth. Results The two‐compartment exchange model extended by an arteriolar compartment (E2CXM) showed the highest fit quality of all LMCA models and the most significant correlation with the Doppler measurements, r  = 0.78 (P  < 0.001). The best correspondence between the capillary perfusion measurements of the LMCA models and those of the 2CBPM was found with the E2CXM (slope of the regression line equal to 1, r  = 0.85, P  < 0.001). The results for the clinical patient data corresponded very well with the results obtained in the animal experiments. Conclusions Double‐contrast agent DCE‐MRI in combination with the E2CXM yields the most reliable results and can be used in clinical routine.

Item Type: Article
Uncontrolled Keywords: DCE-MRI; perfusion; skeletal muscle; tracer kinetic modelling
Divisions: Faculty of Science and Health
Faculty of Science and Health > Computer Science and Electronic Engineering, School of
SWORD Depositor: Elements
Depositing User: Elements
Date Deposited: 19 Jan 2021 09:10
Last Modified: 13 Apr 2022 15:44
URI: http://repository.essex.ac.uk/id/eprint/28147

Actions (login required)